f t g m
Copyright 2017 - PNH is the property of Pennycosta, Netzerotec and Hybrina.com

Energy Audit and Modeling AMEPFS

Energy Audit:

 

Energy Audit Level 1,2 and 3

The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) defines three levels of energy audit;

 

Level I: Site Assessment or Preliminary Audits identify no-cost and low-cost energy saving opportunities, and a general view of potential capital improvements. Activities include an assessment of energy bills and a brief site inspection of your building. 

 Level II: Energy Survey and Engineering Analysis Audits identify no-cost and lowcost opportunities, and also provide EEM (Energy Efficiency Measures) recommendations in line with your financial plans and potential capital-intensive energy savings opportunities. Level II audits include an in-depth analysis of energy costs, energy usage and building characteristics and a more refined survey of how energy is used in your building. 

 Level III: Detailed Analysis of Capital-Intensive Modification Audits (sometimes referred to as an “investment grade” audit) provide solid recommendations and financial analysis for major capital investments. In addition to Level I and Level II activities, Level III audits include monitoring, data collection and engineering analysis.

 Contents of Energy Audit Reports include the following items:

 Level I Audit Report 

· Executive Summary 

· Brief facilities description 

· Scope of audit/ Methodology 

· Preliminary Analysis Findings, including benchmark and end use results 

· List of no-cost and low-cost energy measures 

· Potential measures for further

Level 2 Audit Report 

· All items from Level I Audit 

· More comprehensive energy end use analysis 

· Description of building systems and major equipment 

· Financial analysis of EEMs 

· Description of energy efficiency measures considered and not recommended or not financially viable 

· Description of energy efficiency measures recommended 

· Summary table with measure name, installed cost, energy savings by utility, and O&M savings 

· Capital Intensive measures requiring Level III audit 

· Detailed energy analysis calculations 

· Measurement and verification (M&V) plan for verifying energy savings 

Level 3 Audit Report 

· All items from Level II Audit 

· Detailed information on capital intensive measures – including schematics, equipment lists, equipment specifications, design sequences and costs 

· Highly detailed financial evaluation

Emerging EEMS:

Energy efficiency technology is continuously improving and recent additions to EEMS include the following measures;

Solar Energy: It is estimated that 100 Million houses will be 100 % solar powered by 2020.

Battery Energy Storage: It is being used to store the solar energy during the day time and use it at night.There is an incentive in Germany to install battery storage for the solar power.

Micro CHP (combined heat and power): It is being noticed in the high rise residential building applications to provide backup/power to avoid trapping people in the elevators during power outage, and to reduce the increasing utility bills.  

Hybrid Solar: Solar power is used to charge the car batteries or in house or to send it to Utilities.

Micro Grid: Small towns or communities are grouped together to generate the their own electricity for their own use and form DER (Distributed  Energy Resources).

Demand Response: With demand response system, utilities can downsize the generation capacity requiring less carbon footprint.

Carbon Emission: The amount of carbon emission reduction due to EEMS can be included in the report (optional).  

AMEPFS (Architectural, Mechanical, Electrical, Plumbing, Fire Protection, Structural)

For more information email me at:

This email address is being protected from spambots. You need JavaScript enabled to view it.

www.netzerotec.com